Yellow Dental Air Polisher
- M&Y
- CHINA
- 5Days after payment
2holes/4holes for choose.OEM/ODM acceptable
Sand blasting amount of working head is 2.4g-3.2g/min.Specially designed to prevent backflow and blockage. Steady and efficient stream of powder
Yellow Dental Air Polisher
Description:
1.Yellow dental air polisher is an advanced Air Polisher: a single solution for polishing, perio prevention and maintenance, the device is characterized by unique ergonomics, high precision, trouble-free maintenance and compliance with the highest hygiene standards and from start to the finish it has been designed for maximum performance and minimal discomfort for both the professional and the patient.
2. The air purifier is a compact bicarbonate jet whitening system that quickly connects to a turbine.
3. The air purifier has all the main advantages of a well-known device from a well-known brand:
- Stable and efficient powder flow
- Simple and reliable to use
Technical Details:
Water pressure | 0.2-0.44 MPa |
Air pressure | 0.3-0.4 MPa |
Water spraying amount of working head | 30 ml/min |
Sand blasting amount of working head | 2.4-3.2 g/min |
Connection | 2/4 holes |
Direction of use:
Preparation: Ensure that your dental unit is properly set up and functioning.
Hand Hygiene: Wash your hands thoroughly and put on appropriate personal protective equipment, including gloves and a mask.
Setup: Attach the airotor handpiece to your dental unit's delivery system, making sure it securely clicks into place.
Burr Installation: Load the desired dental burr or instrument into the airotor's chuck by pushing the burr into the chuck and releasing it. Ensure it's properly seated.
Operation: Activate the airotor using the push-button control on the handpiece. This button allows for easy start and stop of the rotation.
Adjustment: Depending on your procedure, adjust the speed and torque settings on your dental unit's control panel to match your requirements.
Dental Procedure: Use the airotor for drilling, cutting, or other dental procedures as needed. Ensure precision and control during the process.
Safety: Be cautious and use appropriate pressure to avoid damaging teeth or soft tissues. Always follow best practices for patient safety.
Completion: After completing the procedure, deactivate the airotor by releasing the push-button control.
Burr Removal: Remove the used burr or instrument carefully, and dispose of it properly according to your clinic's waste disposal protocols.
Cleaning: Thoroughly clean and disinfect the airotor handpiece following your clinic's infection control guidelines.
Maintenance: Regularly maintain and lubricate the airotor as per the manufacturer's recommendations to ensure its longevity and optimal performance.
Storage: Store the airotor in a clean and dry area when not in use, protecting it from contaminants.