Dental External Contra Angle Airmotor Handpiece

  • Dental External Contra Angle Airmotor Handpiece
  • Dental External Contra Angle Airmotor Handpiece
  • Dental External Contra Angle Airmotor Handpiece
  • Dental External Contra Angle Airmotor Handpiece
Dental External Contra Angle Airmotor Handpiece
  • M&Y
  • CHINA
  • 5Days after payment
  • 5000unit/month

Dental External Contra Angle Airmotor Handpiece full sets include contra angle head ,air motor and straight handpiece. aluminun alloy materials ceramic bearings max speed 20000RPM. one year warranty

Dental External Contra Angle Airmotor Handpiece

external water low speed handpiece


Max speedConnectorGear RationBur Type
20000-30000rpmE-type1:1For HP/CA Burs φ2.35
Supply air pressureMotor Connect typePackage sizePackage weight
245-392KPa (2.5-4kgf/cm2)4-Hole/2-Hole16x8x3cm0.3kg

dental low speed handpiece


Dental External Contra Angle Airmotor Handpiece kits are widely used in dental treatment. Dental low-speed machines are mainly used for dental clinical grinding and model grinding, as well as other root canal treatment and implant procedures. Due to the slower speed of the low-speed handpiece, it can do more delicate work during dental treatment.


Dental External Contra Angle Airmotor Handpiece can basically be divided into three parts: straight machine, contra angle and motor.

● Straight handpiece: The straight handpiece is used to apply prophylactic paste on the patient's teeth during dental treatment. It features a swivel cup at the top.

●Contra angle: driven by a motor, it is used to rotate the drill bit and polishing head. Bending machines allow insertion of various rotating instruments.

●Motor: The motor is the power source that drives the dental handpiece to rotate at a low speed.


dental contra angle

1. When using the dental handpiece, it must be lubricated strictly according to the instruction manual. Generally, the high-speed dental handpiece is lubricated twice a day. Low speed handpieces (straight, curved, motor) once a day.


2. The working air pressure of the dental handpiece must be strictly in accordance with the instructions. In general, the working air pressure of two-hole and three-hole dental handpieces is 2-2.2Kg, and the working air pressure of four-hole, five-hole, and six-hole dental handpieces is 2.4-2.5Kg (referring to the pressure at the interface between the dental handpiece and the connecting pipe). The pressure must be adjusted when the new treatment machine is used, and the pressure of the treatment machine must be re-calibrated after a period of use (about one month).


3. Disinfection: high-temperature steam should be used for disinfection, chemical liquid and dry heat should not be used for disinfection. The disinfection temperature is 135°C, and the maximum time should not exceed 30 minutes. It must be cleaned before disinfection and must be lubricated after disinfection. Note: For dental handpieces with quick-change joints, the dental handpieces should be removed, and only the dental handpieces should be disinfected, not the joints. For low-speed dental handpieces, please remove the straight and curved handpieces for disinfection. Use alcohol to clean the dental handpiece when it is dirty.


4. Do not use standard, rusty or aging burs or grinding heads.


5. Gland The high-speed dental handpiece must not press the gland when it is rotating, so as not to damage the movement. Straight and bending machines cannot load and remove burs when they are rotating.


6. The bur, grinding head or "standard rod" should be removed and installed once a day, so as to avoid rusting of the bur if it is not removed for a long time.

external water low speed handpiece